Migrate from previous versions of OPC Publisher to 2.9 and higher
Table Of Contents
- Why the changes from 2.8 to 2.9?
- Breaking changes
- Upgrading OPC Publisher published nodes configuration file (pn.json)
- Command Line Arguments
- Direct Method compatibility
- OPC Publisher 2.5.x direct methods supported in 2.8.2
- OPC Publisher 2.5.x direct methods not supported in 2.8.2
Why the changes from 2.8 to 2.9?
Customers told us they want to leverage the capabilities of OPC Twin. However, deploying and operating a micro service architecture is often times too costly and too difficult for them. Many times customers were already using an Azure IoT Hub instance to manage other devices and wanted to leverage this instance also for OPC UA enabled assets. What they were looking for was the standalone version of OPC Publisher but with its capabilities extended to provide read/write/call capabilities also.
We also found significant problems with the orchestration approach in OPC Publisher to continue its development. For one, the size constraints imposed by keeping the entire configuration of a publisher in a single document in Cosmos DB became an issue for some customers. And the overhead of the communication between publisher and cloud services and the need for a second cloud connection bypassing IoT Edge were a problem for stable and reliable production use.
We reacted by combining all 3 edge modules into OPC Publisher 2.9 and combining all cloud services into a single web service that is now optional. Yes, you can directy interact with OPC Publisher through IoT Hub or MQTT/HTTP (Preview). We also updated OPC Publisher to leverage .net 8 performance improvements and to use more defensive coding and code analysis moving the code base forward.
Breaking changes
We provided backwards compatibility (e.g., you need to use the -c
, --strict
command line argument to enable standards compliance) in OPC Publisher. OPC Publisher 2.9 is therefore a drop in replacement for OPC Publisher 2.8 in standalone mode with the following exceptions:
- Log levels specified through the
--loglevel
command line option have been aligned to standard .net log levels, e.g., to specify verbose logging, useTrace
.
However, if you were using the 2.8 micro services before then you must be aware of the following breaking changes:
- Due to the simplification of the cloud services we removed the IAI installer and Helm chart support. It is still possible to deploy the web api container in AKS but we do not provide any tooling to do that.
- OPC Publisher 2.9 removes “orchestrated mode”. This means you must migrate your Cosmos DB job definitions using the migration tooling.
- We also removed the telemetry processors and the secondary event hub to read the proprietary data set messages from. To migrate change your event hub processor or ingestion code to read OPC Publisher telemetry messages directly from IoT Hub event hub compatible endpoint.
- We retained Open API compatibility to the 2.8 cloud service API in the new OPC Publisher cloud web service’s API. This includes using the same route paths as in the AKS hosted version of the 2.8 platform. However, the following API changes were made:
- OPC Publisher 2.9 does not support activation and deactivation of Endpoint Twins, which allowed OPC Twin endpoints to be addressed with a IoT Hub device id. Instead all API’s must be invoked with a
ConnectionModel
parameter (connection
) and the original request model. - The concept of supervisor (the OPC Twin module instance) and discoverer (the OPC Discovery module instance) are completely equivalent to the publisher concept in 2.9. The supervisor, discovery, and publisher REST APIs have been retained for backwards compatibility and return the same information which is the twin of the Publisher module. However, this also means there is no migration from OPC Twin or OPC Discovery to OPC Publisher 2.9, settings have to be re-applied.
- With removal of the database and orchestrated mode we changed the existing Publishing API to directly update the publisher configuration which has different performance characteristics than in 2.8 especially for the bulk publishing API.
- The GetSupervisorStatus and ResetSupervisor API has been removed without replacement.
- GetEndpointCertificate API now returns a
X509CertificateChainModel
instead of a byte array in 2.8. - OPC Discovery capabilities are integrated into OPC Publisher 2.9.
- OPC Publisher 2.9 does not support activation and deactivation of Endpoint Twins, which allowed OPC Twin endpoints to be addressed with a IoT Hub device id. Instead all API’s must be invoked with a
Migrating Cosmos DB job definitions
COMING SOON
Upgrading OPC Publisher published nodes configuration file (pn.json)
OPC Publisher can consume published nodes JSON files version 2.5.x or higher without any modifications.
Each OPC Publisher since has added new fields to configure publishing but maintained backwards compatibilty with older versions, such as 2.5.x.
The full schema of published nodes JSON file that works in all versions since 2.5.* looks like this:
[
{
"EndpointUrl": "string",
"UseSecurity": "boolean",
"OpcAuthenticationMode": "string",
"OpcAuthenticationUsername": "string",
"OpcAuthenticationPassword": "string",
"DataSetWriterGroup": "string",
"DataSetWriterId": "string",
"DataSetPublishingInterval": "integer",
"DataSetPublishingIntervalTimespan": "string",
"Tag": "string",
"OpcNodes": [
{
"Id": "string",
"ExpandedNodeId": "string",
"DataSetFieldId ": "string",
"DisplayName": "string",
"OpcSamplingInterval": "integer",
"OpcSamplingIntervalTimespan": "string",
"OpcPublishingInterval": "integer",
"OpcPublishingIntervalTimespan": "string",
"HeartbeatInterval": "integer",
"HeartbeatIntervalTimespan": "string",
"SkipFirst": "bool",
"QueueSize": "integer"
}
]
}
]
For details of each field you can consult the direct methods API documentation as the fields of published nodes JSON schema map directly to that of direct method API calls.
The only difference is that OpcAuthenticationUsername
and OpcAuthenticationPassword
are refereed to as UserName
and Password
in direct method API calls.
Please note that OPC Publisher 2.9 can still consume legacy NodeId
-based node definitions (as can be found in publishednodes_2.5.json
), but we strongly recommend to use OpcNodes
-based definitions instead. Please consider migrating your old published nodes JSON files that use NodeId
to the newer schema.
Command Line Arguments
To learn more about how to use comman-line arguments to configure OPC Publisher, please refer to this doc.
OPC Publisher 2.5.x Command Line Arguments supported in 2.8.2 or higher
Any removed command line arguments will still silently work.
The following table describes the command line arguments, which were available in OPC Publisher 2.5.x and their compatibility in OPC Publisher 2.8.2 and above.
Command Line Options | in 2.8.2 and above | Alternative |
---|---|---|
–pf, –publishfile=VALUE | yes | |
–tc, –telemetryconfigfile=VALUE | no | |
–s, –site=VALUE | yes | |
–ic, –iotcentral | no | |
–sw, –sessionconnectwait=VALUE | no | |
–mq, –monitoreditemqueuecapacity=VALUE | no | use –om, –maxoutgressmessages=VALUE |
–di, –diagnosticsinterval=VALUE | yes | |
–ns, –noshutdown=VALUE | no | |
–rf, –runforever | no | |
–lf, –logfile=VALUE | no | IoT Edge support bundle or live logs |
–lt, –logflushtimespan=VALUE | no | IoT Edge support bundle or live logs |
–ll, –loglevel=VALUE | yes | |
–ih, –iothubprotocol=VALUE | yes | |
–ms, –iothubmessagesize=VALUE | yes | |
–si, –iothubsendinterval=VALUE | yes | |
–dc, –deviceconnectionstring=VALUE | yes | |
–c, –connectionstring=VALUE | no | use –dc, –deviceconnectionstring=VALUE |
–hb, –heartbeatinterval=VALUE | yes | |
–sf, –skipfirstevent=VALUE | yes (2.9.0 or above) | same as –skipfirst=VALUE |
–pn, –portnum=VALUE | no | |
–pa, –path=VALUE | no | |
–lr, –ldsreginterval=VALUE | no | |
–ol, –opcmaxstringlen=VALUE | yes | |
–ot, –operationtimeout=VALUE | yes | |
–oi, –opcsamplinginterval=VALUE | yes | |
–op, –opcpublishinginterval=VALUE | yes | |
–ct, –createsessiontimeout=VALUE | yes | |
–ki, –keepaliveinterval=VALUE | yes | |
–kt, –keepalivethreshold=VALUE | yes | |
–aa, –autoaccept | yes | |
–tm, –trustmyself=VALUE | yes | |
–to, –trustowncert | no | same as –tm, –trustmyself |
–fd, –fetchdisplayname=VALUE | yes | |
–fn, –fetchname | no | same as –fd, –fetchdisplayname |
–ss, –suppressedopcstatuscodes=VALUE | no | |
–at, –appcertstoretype=VALUE | yes | |
–ap, –appcertstorepath=VALUE | yes | |
–tp, –trustedcertstorepath=VALUE | yes | |
–rp, –rejectedcertstorepath=VALUE | yes | |
–ip, –issuercertstorepath=VALUE | yes | |
–csr | no | |
–ab, –applicationcertbase64=VALUE | no | |
–af, –applicationcertfile=VALUE | no | |
–pb, –privatekeybase64=VALUE | no | |
–pk, –privatekeyfile=VALUE | no | |
–cp, –certpassword=VALUE | no | |
–tb, –addtrustedcertbase64=VALUE | no | |
–tf, –addtrustedcertfile=VALUE | no | |
–ib, –addissuercertbase64=VALUE | no | |
–if, –addissuercertfile=VALUE | no | |
–rb, –updatecrlbase64=VALUE | no | |
–uc, –updatecrlfile=VALUE | no | |
–rc, –removecert=VALUE | no | |
–dt, –devicecertstoretype=VALUE | no | |
–dp, –devicecertstorepath=VALUE | no | |
-i, –install | no | |
-h, –help | yes | |
–st, –opcstacktracemask=VALUE | no | |
–sd, –shopfloordomain=VALUE | no | same as –s, –site option |
–vc, –verboseconsole=VALUE | no | |
–as, –autotrustservercerts=VALUE | no | same as –aa, –acceptuntrusted |
–autoaccept=VALUE | yes | same as –aa, –acceptuntrusted |
–tt, –trustedcertstoretype=VALUE | no | env variable TrustedPeerCertificatesType=VALUE |
–rt, –rejectedcertstoretype=VALUE | no | env variable RejectedCertificateStoreType=VALUE |
–it, –issuercertstoretype=VALUE | no | env variable TrustedIssuerCertificatesType=VALUE |
Direct Method compatibility
OPC Publisher version 2.8.2 and above implements IoT Hub Direct Methods, which can be called from applications using the IoT Hub Device SDK.
The direct method request payload of OPC Publisher 2.8.2 and above is backwards compatible with OPC Publisher 2.5.x direct methods. The payload schema allows also configuration of attributes introduced in pn.json
in OPC Publisher 2.6.x and above (for example: DataSetWriterGroup, DataSetWriterId, QueueSize per node, …)
Limitations: Continuation points for GetConfiguredEndpoints and GetConfiguredNodesOnEndpoint aren’t available in 2.8.2 or above. Instead a chunking protocol is used when the .net sdk packages are used.
Note: The objects and primitives names in the direct method payload api model are camel case formatted in 2.8.2. This follows the guidelines of the rest of the api models through the IIoT Platform. Since the names in json payloads in 2.5.x are pascal case formed, we highly recommend enabling case-insensitive Json parsing in your direct methods based configuration tool. You can find details on json case-insensitive serialization here: how to enable case-insensitive property name matching with System.Text.Json, or here: Newtonsoft Json Serialization Naming Strategy
OPC Publisher 2.5.x direct methods supported in 2.8.2
The following table describes the direct methods, which were available in OPC Publisher 2.5.x with their request and response payloads.
MethodName | Request | Response | in 2.8.2 and above |
---|---|---|---|
PublishNodes | EndpointUrl, List<OpcNodes>, UseSecurity, UserName, Password | Status, List<StatusResponse> | Yes |
UnpublishNodes | EndpointUrl, List<OpcNodes> | Status, List<StatusResponse> | Yes |
UnpublishAllNodes | EndpointUrl | Status, List<StatusResponse> | Yes |
GetConfiguredEndpoints | - | List<EndpointUrl> | Yes |
GetConfiguredNodesOnEndpoint | EndpointUrl | EndpointUrl, List< OpcNodeOnEndpointModel > where OpcNodeOnEndpointModel contains: Id ExpandedNodeId OpcSamplingInterval OpcPublishingInterval DisplayName HeartbeatInterval | Yes |
GetDiagnosticInfo | - | DiagnosticInfoMethodResponseModel | Yes |
GetDiagnosticLog | - | MissedMessageCount, LogMessageCount, List<Log> | No* |
GetDiagnosticStartupLog | - | MissedMessageCount, LogMessageCount, List<Log> | No* |
ExitApplication | SecondsTillExit (optional) | StatusCode, List<StatusResponse> | No* |
GetInfo | - | GetInfoMethodResponseModel | No* |
*This functionality is provided by direct methods of the IoT Edge edgeAgent
module. For more information, see “Communicate with edgeAgent using built-in direct methods”.
An outdated, archived sample application used to configure OPC Publisher 2.5.x can be used to configure OPC Publisher 2.8.2.
For new applications, direct method names with a _V2
suffix should be used. For backward compatibility of older applications direct method names without the _V2
suffix are supported, but are subject of deprecation.
PublishNodes (PublishNodes_V1)
Request
{
"EndpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000",
"UseSecurity": false,
"OpcNodes":[
{
"Id": "nsu=http://microsoft.com/Opc/OpcPlc/Boiler;s=Boiler"
},
{
"Id": "nsu=http://microsoft.com/Opc/OpcPlc/;s=65e451f1-56f1-ce84-a44f-6addf176beaf"
},
{
"Id": "nsu=http://microsoft.com/Opc/OpcPlc/;s=FastUInt1"
}
]
}
Response
(2.5.x)
{
"status": 200,
"payload": [
"'nsu=http://microsoft.com/Opc/OpcPlc/Boiler;s=Boiler': added",
"'nsu=http://microsoft.com/Opc/OpcPlc/;s=65e451f1-56f1-ce84-a44f-6addf176beaf': added",
"'nsu=http://microsoft.com/Opc/OpcPlc/;s=FastUInt1': added"
]
}
Response
(2.8.2)
{
"status": 200,
"payload": {}
}
GetConfiguredEndpoints (GetConfiguredEndpoints_V1)
Request
{}
Response
(2.5.x)
Without any configured endpoints:
{
"status": 200,
"payload":
{
"Endpoints": []
}
}
With configured endpoints:
{
"status": 200,
"payload":
{
"Endpoints": [
{
"EndpointUrl":"opc.tcp://sandboxhost-637811493394507132:50000"
}
]
}
}
Response
(2.8.2)
Without configured endpoints:
{
"status": 200,
"payload":
{
"endpoints": []
}
}
With configured endpoints:
{
"status": 200,
"payload":
{
"endpoints": [
{
"endpointUrl":"opc.tcp://sandboxhost-637811493394507132:50000"
}
]
}
}
GetConfiguredNodesOnEndpoint (GetConfiguredNodesOnEndpoint_V1)
Request
{
"EndpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000"
}
Response
(2.5.x)
{
"status": 200,
"payload": {
"EndpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000",
"OpcNodes": [
{
"Id": "nsu=http://microsoft.com/Opc/OpcPlc/Boiler;s=Boiler"
},
{
"Id": "nsu=http://microsoft.com/Opc/OpcPlc/;s=65e451f1-56f1-ce84-a44f-6addf176beaf"
},
{
"Id": "nsu=http://microsoft.com/Opc/OpcPlc/;s=FastUInt1"
}
]
}
}
If UnpublishAllNodes
is called on that endpoint, then the response will be:
{
"status": 200,
"payload": {
"endpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000",
"opcNodes": []
}
}
Response
(2.8.2)
{
"status":200,
"payload":
{
"opcNodes": [
{
"id": "nsu=http://microsoft.com/Opc/OpcPlc/Boiler;s=Boiler"
},
{
"id": "nsu=http://microsoft.com/Opc/OpcPlc/;s=65e451f1-56f1-ce84-a44f-6addf176beaf"
},
{
"id": "nsu=http://microsoft.com/Opc/OpcPlc/;s=FastUInt1"
}
]
}
}
If the endpoint isn’t configured or UnpublishAllNodes
is called on that endpoint, then the response will be:
{
"status": 404,
"payload": "Endpoint not found: opc.tcp://sandboxhost-637811493394507132:50000/"
}
GetDiagnosticInfo (GetDiagnosticInfo_V1)
Request
{}
Response
(2.5.x)
{
"status": 200,
"payload": {
"PublisherStartTime": "2022-02-22T18:07:56.363511Z",
"NumberOfOpcSessionsConfigured": 1,
"NumberOfOpcSessionsConnected": 0,
"NumberOfOpcSubscriptionsConfigured": 1,
"NumberOfOpcSubscriptionsConnected": 0,
"NumberOfOpcMonitoredItemsConfigured": 3,
"NumberOfOpcMonitoredItemsMonitored": 0,
"NumberOfOpcMonitoredItemsToRemove": 0,
"MonitoredItemsQueueCapacity": 8192,
"MonitoredItemsQueueCount": 0,
"EnqueueCount": 13060,
"EnqueueFailureCount": 0,
"NumberOfEvents": 13060,
"SentMessages": 30,
"SentLastTime": "2022-02-22T19:03:39.3249082Z",
"SentBytes": 3000192,
"FailedMessages": 0,
"TooLargeCount": 0,
"MissedSendIntervalCount": 8,
"WorkingSetMB": 118,
"DefaultSendIntervalSeconds": 10,
"HubMessageSize": 262144,
"HubProtocol": 3
}
}
Response
(2.8.2)
{
"status": 200,
"payload": [
{
"endpoint": {
"endpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000",
"dataSetWriterGroup": "Asset1",
"useSecurity": false,
"opcAuthenticationMode": "UsernamePassword",
"opcAuthenticationUsername": "Usr"
},
"sentMessagesPerSec": 2.6,
"ingestionDuration": "{00:00:25.5491702}",
"ingressDataChanges": 25,
"ingressValueChanges": 103,
"ingressBatchBlockBufferSize": 0,
"encodingBlockInputSize": 0,
"encodingBlockOutputSize": 0,
"encoderNotificationsProcessed": 83,
"encoderNotificationsDropped": 0,
"encoderIoTMessagesProcessed": 2,
"encoderAvgNotificationsMessage": 41.5,
"encoderAvgIoTMessageBodySize": 6128,
"encoderAvgIoTChunkUsage": 1.158034,
"estimatedIoTChunksPerDay": 13526.858105160689,
"outgressBatchBlockBufferSize": 0,
"outgressInputBufferCount": 0,
"outgressInputBufferDropped": 0,
"outgressIoTMessageCount": 0,
"connectionRetries": 0,
"opcEndpointConnected": true,
"monitoredOpcNodesSucceededCount": 5,
"monitoredOpcNodesFailedCount": 0,
"ingressEventNotifications": 0,
"ingressEvents": 0
}
]
}
UnpublishNodes (UnpublishNodes_V1)
If OpcNodes is omitted, then all nodes are unpublished and the endpoint is removed.
Request
{
"EndpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000",
"OpcNodes": [
{
"Id":"nsu=http://microsoft.com/Opc/OpcPlc/;s=65e451f1-56f1-ce84-a44f-6addf176beaf"
}
]
}
Response
(2.5.x)
{
"status": 200,
"payload": [
"Id 'nsu=http://microsoft.com/Opc/OpcPlc/;s=65e451f1-56f1-ce84-a44f-6addf176beaf': tagged for removal"
]
}
Response
(2.8.2)
{
"status": 200,
"payload": {}
}
UnpublishAllNodes (UnpublishAllNodes_V1)
Request
{
"EndpointUrl": "opc.tcp://sandboxhost-637811493394507132:50000"
}
Response
(2.5.x)
{
"status": 200,
"payload": [
"All monitored items in all subscriptions on endpoint 'opc.tcp://sandboxhost-637811493394507132:50000' tagged for removal"
]
}
Response
(2.8.2)
{
"status": 200,
"payload": {}
}
OPC Publisher 2.5.x direct methods not supported in 2.8.2
The direct methods not available in OPC Publisher 2.8.2, there are changes required to apply to the applications, which do use them.
GetDiagnosticLog
To retrieve the logs of an IoT Edge module, please check the built-in direct methods provided by IoT Edge edgeAgent
module here.
GetDiagnosticStartupLog
To get diagnostic info of OPC Publisher, please refer to this link.
ExitApplication
If OPC Publisher is in failed state or other unhealthy behavior, you could trigger RestartModule
direct method to stop and then restart the module. To learn more about this direct method, please have a look at this in-built direct method provided by IoT Edge.
GetInfo
To get the info like version, OS, etc., please refer to the properties provided by IoT Edge which is documented here.