Environment variable name | Description | Mandatory |
---|---|---|
ENABLE_GATEWAY | Indicates whether the edgeHub gateway should be enabled or not | No (defaults to true ) |
HTTPS_PROXY | HTTPS proxy url | No |
RX2_DATR | RX2 data rate; useful to override the default regional RX2 Data Rate at a global level | No (defaults to null, regional default value is used) |
RX2_FREQ | RX2 frequency; useful to override the default regional RX2 Frequency at a global level | No (defaults to null, regional default value is used) |
FACADE_SERVER_URL | Azure Facade function url, e.g. https://deployedfunction.azurewebsites.net/api | Yes |
FACADE_AUTH_CODE | Azure Facade function auth code | Yes |
LOG_LEVEL | Logging level | No (defaults to level 4 (Error) |
LOG_TO_CONSOLE | Indicates whether logging to console is enabled or not | No (default to true ) |
LOG_TO_TCP | Indicates whether logging to TCP is enabled or not (used mainly for integration tests) | No (defaults to false ) |
LOG_TO_HUB | Indicates whether logging to IoT Hub is enabled or not | No (defaults to false ) |
LOG_TO_TCP_ADDRESS | IP address for TCP logs | Yes, only if TCP logging is enabled |
LOG_TO_TCP_PORT | TCP port to send logs to | Yes, only if TCP logging is enabled |
NETID | Gateway network ID | No (defaults to network id 1) |
AllowedDevAddresses | List of allowed dev addresses from which message processing is enabled. | No (by default allows all messages coming from the defined NETID to be processed) |
LNS_SERVER_PFX_PATH | Path of the .pfx certificate to be used for LNS Server endpoint | No |
LNS_SERVER_PFX_PASSWORD | Password of the .pfx certificate to be used for LNS Server endpoint | No |
CLIENT_CERTIFICATE_MODE | Specifies the client certificate mode with which the server should be run | No (defaults to NoCertificate ) |
LNS_VERSION | Version of the LNS | No |
IOTHUB_CONNECTION_POOL_SIZE | AMQP Connection Pool Size for communication to IoT Edge Hub / IoT Hub (depending on ENABLE_GATEWAY ). Increasing this value to higher number will improve scalability; for more information see Scalability |
No (defaults to 1) |
APPLICATIONINSIGHTS_CONNECTION_STRING | Connection string for forwarding metrics to Application Insights | No |
The following settings can be configured via desired properties of the Network Server module twin in IoT Hub:
Property name | Description | Mandatory |
---|---|---|
FacadeServerUrl | Azure Facade function url | Yes |
FacadeAuthCode | Azure Facade function auth code | Yes |
ProcessingDelayInMilliseconds | Processing delay (in milliseconds) to be used for the LNS not owning the connection for a device in a multi-gateway scenario; for more information see Scalability | No (defaults to 400 ms) |
Cloud-based Network Server configuration
You can run the Network Server directly in the cloud without requiring IoT Edge, e.g. on an AKS cluster. In general, the same environment variables as for the module configuration apply (e.g. for the facade connection). In addition make sure to set the following environment variables:
Environment variable name | Description | Mandatory |
---|---|---|
CLOUD_DEPLOYMENT | Switch to indicate that the LNS is deployed as a standalone cloud-based instance | Yes (must be set to true) |
ENABLE_GATEWAY | Gateway mode is only applicable to IoT Edge-based deployments. Must be set to false or unset. |
No |
IOTHUBHOSTNAME | Host name of the IoT Hub to which the LNS should connect to. | Yes |
HOSTNAME | Identifier of the LNS. | Yes |
REDIS_CONNECTION_STRING | Connection string used to connect to the deployed Redis instance. | Yes |
FACADE_SERVER_URL | Azure Facade function url, e.g. https://deployedfunction.azurewebsites.net/api | Yes |
FACADE_AUTH_CODE | Azure Facade function auth code | Yes |